Keto Ply manufactures pressure impregnated fire retardant plywood at Yamunanagar and supplies it across Chirawa to Shekhawati haveli restoration, school and college projects and the Jhunjhunu and Pilani belt, in 4 mm to 25 mm boards.
IS 5509 | BWR Bonded | 4 mm to 25 mm
Chirawa sits in the Shekhawati belt, where painted havelis are being restored as boutique stays and where diaspora money has funded a dense network of schools, colleges and hostels, with the Pilani education corridor next door. Restoration work puts new joinery into old timber buildings and institutional work puts it into sleeping occupancies, and both are cases where the fire officer looks at the panel specification rather than taking it on trust. Keto Ply fire retardant plywood is treated by pressure impregnation before pressing, so the retardant chemistry sits inside the veneer rather than on top of it. Sanding, cutting and edge banding on site do not remove the protection.
Flammability, flame penetration and rate of burning checks are run on production batches before the consignment is dispatched.
Chemistry impregnated right through the veneer, so cutting and sanding on site never exposes untreated wood underneath.
Direct dispatch to Chirawa, Jhunjhunu, Pilani, Surajgarh and Bissau sites, with delivery scheduled against the site programme.
Every Keto Ply panel carries the brand's borer, fungus and anti-termite guarantee in writing.
Six things Chirawa contractors, architects and turnkey joinery firms check before a panel goes into a fire clearance drawing, and how Keto FR plywood answers each one.
Request a Sample BoardRetardant salts are driven into the veneer under pressure before pressing, so the board resists ignition through its full section instead of only at the face.
Once the flame source is removed, treated veneers char instead of continuing to burn. That is the mechanism behind the IS 5509 flammability and rate of burning criteria.
Shekhawati summers are dry and severe, and they strip moisture out of untreated timber until it catches easily. Pressure impregnation puts the retardant inside the veneer and BWR bonding holds the glue line through heat, dust and cold nights.
The same treatment cycle carries the Keto Ply anti-termite and anti-fungus guarantee, so one panel handles both fire and biological protection.
Kiln plus air seasoning and calibrated sanding hold thickness within IS tolerance, so laminate and veneer lay flat across large wall panels and shutters.
Supplied from the Yamunanagar unit with dealer and project pricing for Chirawa, plus dealership openings across Jhunjhunu and the Shekhawati belt.
Acceptance values laid down in IS 5509 (Fire Retardant Plywood - Specification), tested as per IS 1734 (Part 3).
| Test | Method | Requirement | What it means on site |
|---|---|---|---|
| Flammability | IS 1734 (Part 3) | Second ignition not before 30 minutes | The panel resists re-ignition through half an hour of direct exposure. |
| Flame Penetration | IS 1734 (Part 3) | Minimum 15 minutes for every 6 mm thickness | A 12 mm board resists burn through for roughly 30 minutes. |
| Rate of Burning | IS 1734 (Part 3) | 30% to 70% weight loss in not less than 20 minutes | Combustion proceeds slowly, which buys evacuation time. |
| Bonding / Adhesion | IS 303 - BWR Grade | Pass | Boiling water resistant glue line, required for treatability. |
These are the published IS 5509 acceptance criteria for fire retardant plywood. The lot specific third party test certificate is issued with every project consignment.
Dealer supply and direct project dispatch across the Shekhawati belt:
Not seeing your area? Keto Ply is appointing dealers across Chirawa and the Shekhawati belt. Send a dealership enquiry and our territory manager will call back.
Share your thickness, square footage and delivery city. We will send the price list along with the current test certificate.